Multiloop Control of Continuous Stirred Tank Reactor Using Biggest Log Modulus Method

Authors

  • S. Anbu Assistant Professor, Department of Electronics and Instrumentation Engineering, Annamalai University, Annamalai nagar, Tamil Nadu, India

DOI:

https://doi.org/10.51983/ajes-2016.5.2.1977

Keywords:

CSTR, MIMO, SISO, BLT, Multiloop

Abstract

A majority of the chemical processes are naturally a Multi Input Multi Output (MIMO) system because of the existence of many loops where the interactions between the loops are high. In a Single Input Single Output (SISO) control, the primary objective is to maintain only one variable nearer to its set point, though several measured variables are involved. In contrast to SISO system, the MIMO control involves maintaining several controlled variables at their relevant setpoints simultaneously, Cha et al. (2002). For controlling MIMO systems, a single loop tuned controller design procedure cannot be directly applied because of the heavy interaction among the loops.. A Continuous Stirred Tank Reactor (CSTR) is one of the versatile reactors which find its application in many chemical and petrochemical industries, exhibiting reasonably high non-linear behaviour. The control of CSTR throws a challenge to the control engineers to design a well-suited controller for its smooth operation. The interaction in the CSTR is phenomenal and hence in this present work, the Biggest Log modulus Tuning (BLT) is designed for the CSTR and performances are evaluated under various operating conditions through simulation.

References

S. Anbu and N. Jaya, "Design of gain scheduling adaptive control for continuous stirred tank reactor," International Journal of Automation and Control, vol. 8, no. 2, pp. 141-157, 2014.

J. C. Basilio and S. R. Matos, "Design of PI and PID controllers with transient performance specification," IEEE Transactions on Education, vol. 45, no. 4, pp. 364-370, 2002.

B. W. Bequette, Process Control: Modeling, Design, and Simulation. Prentice Hall Professional, 2003.

J. M. Böling, D. E. Seborg, and J. P. Hespanha, "Multi-model adaptive control of a simulated pH neutralization process," Control Engineering Practice, vol. 15, no. 6, pp. 663-672, 2007.

S. Cha, D. Chun, and J. Lee, "Two-step IMC−PID method for multiloop control system design," Industrial & Engineering Chemistry Research, vol. 41, no. 12, pp. 3037-3041, 2002.

E. H. Bristol, "On a new measure of interaction for multivariable process control," IEEE Trans. Automat. Control, vol. AC-11, pp. 133-134, 1966.

N. Kamala, T. Thyagarajan, and S. Renganathan, "Multivariable control of Nonlinear Process," Int. J. of Recent Trends in Engineering and Technology, vol. 4, no. 4, pp. 106-110, 2010.

W. L. Luyben, "Simple method for tuning SISO controllers in multivariable systems," Industrial & Engineering Chemistry Process Design and Development, vol. 25, no. 3, pp. 654-660, 1986.

T. J. Monica, C. C. Yu, and W. L. Luyben, "Improved multiloop single-input/single-output (SISO) controllers for multivariable processes," Industrial & Engineering Chemistry Research, vol. 27, no. 6, pp. 969-973, 1988.

M. Senthilkumar and S. A. Lincon, "Design of stabilizing PI controller for coupled tank MIMO process," International Journal of Engineering Research and Development, vol. 3, no. 10, pp. 47-55, 2012.

N. F. Thornhill, S. C. Patwardhan, and S. L. Shah, "A continuous stirred tank heater simulation model with applications," Journal of Process Control, vol. 18, no. 3, pp. 347-360, 2008.

Q. G. Wang, T. H. Lee, and Y. Zhang, "Multiloop Version of the Modified Ziegler-Nichols Method for Two Input Two Output Processes," Industrial & Engineering Chemistry Research, vol. 37, no. 12, pp. 4725-4733, 1998.

Downloads

Published

17-10-2016

How to Cite

Anbu, S. (2016). Multiloop Control of Continuous Stirred Tank Reactor Using Biggest Log Modulus Method. Asian Journal of Electrical Sciences, 5(2), 54–61. https://doi.org/10.51983/ajes-2016.5.2.1977